ISEAFrame  2.26.1
XML options

Global options can be set within the <Options> node. Depending on the simulation type, the following options can be set:

Electrical model

XML Tag Unit/Type Default value Explanation
StepTime s 1.0 Maximum time that is simulated electrically before switching to the thermal model, see the simulation cycle
PowerStopCriterion % 1.0 If a power profile is used, this determines the maximum deviation from the power value given in the profile before the simulation step is stopped and the current is readjusted.
SocStopCriterion % 5.0 Maximum value any SOC can change by during an electrical simulation step before switching to the thermal model. This is a percentage of the cell capacity, not of the SOC value at the beginning of the timestep.
ThermalStopCriterionInDegreeC °C 5.0 Maximum temperature change in any thermal state during a thermal simulation step before the electrcal simulation is reset.
Cycles int > 0 1 Gives the number of times the current/power profile is executed by the thermal-electrical standalone
SampleRate Hz 1.0e6 Sample rate for the automatic simplification of fast time constants, see automatic simplification
MaximalOperationalCellVoltageV V 10.0 Maximum voltage of the simulated cells. If any cell voltage goes above this limit, values from the current profile are skipped until a negative value / discharge is found.
MinimalOperationalCellVoltageV V 0.0 Minimum voltage of the simulated cells. If any cell voltage goes below this limit, values from the current profile are skipped until a positive value / charge is found.
VerificationDelayForVoltageLimitSteps Steps 4 Number of electrical simulations steps before the breach of the operational limits is verified again. This allows the electrical model to "leave" the boundaries.

Thermal model

XML Tag Unit/Type Default value Explanation
AirTemperature °C Ambient temperature
- Attribute ReadFromFile bool If this attribute is given, the air temperature is read as a profile from the specified file. The file has to be in CSV format, similarly to the current/power profile.
ConvectionActivated bool De-/activates free convection as default cooling mechanism
- Attribute anvancedAreaAggregation bool true If set to false, all coplanar areas are combined to one single area and its specific dimensions are calculated. If set to true, the position of the thermal block is analyzed to separate the calculations for coplanar but unconnected areas.
RadiationActivated bool De-/activates thermal radiation as standard cooling
GeometricalTolerance Sets the geometrical tolerance of the thermal model
- Attribute length m 1.0e-6 Maximum distance between two objects to be assumed as connected
- Attribute angleInDegrees ° 1.0e-3 Maximum difference between two angles to be regarded as equal
- Attribute percentOfQuantity % 0.1 Maximum difference between two quantities to be regarded as equal

Aging model

These options for the aging simulation must be added in <Configuration><Options><Aging>.

XML Tag Unit/Type Default value Explanation
CalculationCycles int > 0 1 Number of times the current or power profile is simulated before each aging step
SteadyStateCycles CalculationCycles > int >= 0 0 Number of cycles in CalculationCycles that are simulated without collecting data for aging
AgingSteps int > 0 1 Number of aging steps
AgingStepTime days Duration of each aging step